Frigidaire FDR25S1 Dehumidifier Manual

The Frigidaire FDR25S1 is a 25-pint capacity dehumidifier designed for medium-sized rooms up to 1500 sq. ft. It features automatic humidity control, continuous drainage option, washable air filter, electronic controls with digital display, auto-restart after power interruption, and a built-in carrying handle. Below are key sections for safety, features, installation, setup, operation, maintenance, and troubleshooting.

1. Features at a Glance 2. Installation 3. First-Time Setup 4. Specifications 5. Controls and Settings 6. Connecting Drainage 7. Operation Modes 8. Maintenance 9. Care & Cleaning 10. Regulatory Information 11. Troubleshooting

Features at a Glance

Key components: Electronic control panel, water collection bucket, continuous drain hose connection, washable air filter, built-in carrying handle, and digital humidity display.

FeatureDescription
Capacity25 pints per day (at 60°F, 60% RH)
Coverage AreaUp to 1500 square feet
Humidity ControlAutomatic with adjustable set point (35%-85%)
Water Removal2.3-gallon bucket with full alert and auto shut-off
Continuous DrainageGarden hose adapter for permanent drainage
Air FilterWashable mesh filter for air purification
ControlsElectronic touchpad with digital display
Auto RestartResumes previous settings after power outage
Carrying HandleIntegrated for easy portability
Power Source115V, 60Hz, 3.5 amps

Installation

Unpack and inspect contents. Place on level surface.

  1. Positioning: Place at least 12 inches from walls and furniture for proper airflow.
  2. Bucket installation: Insert empty water collection bucket securely until it clicks.
  3. Continuous drainage (optional): Attach garden hose to drain port at rear.
  4. Power connection: Plug into grounded 115V outlet.

WARNING! Do not operate in temperatures below 41°F (5°C). Ensure unit is upright for 24 hours before first use if transported sideways.

First-Time Setup

Power on dehumidifier; follow initial setup steps.

  1. Set desired humidity: Press HUMIDITY button to select 45%-55% for typical comfort.
  2. Select fan speed: Choose HIGH for faster dehumidification or LOW for quiet operation.
  3. Check filter: Ensure washable filter is clean and properly installed.
  4. Test operation: Run for 15 minutes to confirm proper condensation and drainage.

CAUTION! Place on level surface to prevent water leakage. Do not block air intake or exhaust.

Specifications

Controls and Settings

Electronic control panel with digital display and touch buttons.

Control Panel: POWER, HUMIDITY SET, FAN SPEED (HIGH/LOW), TIMER, FILTER RESET, CONTINUOUS MODE.

Display shows: Current room humidity, set humidity, fan speed, filter alert, bucket full indicator, timer status.

Settings: Humidity set point (35%-85%), 24-hour timer (1-24 hours), continuous operation mode, fan speed selection, filter reset after cleaning.

Connecting Drainage

For continuous operation without emptying bucket.

  1. Turn off and unplug unit.
  2. Remove bucket from front compartment.
  3. Attach standard garden hose (¾") to drain port at rear.
  4. Route hose to floor drain, sink, or outside.
  5. Replace bucket (required for proper operation even with hose).
  6. Select CONTINUOUS mode on control panel.

Tip: Ensure hose has downward slope without kinks for proper drainage.

Operation Modes

Multiple operating modes for different needs.

  1. Auto Mode: Maintains set humidity level automatically.
  2. Continuous Mode: Runs continuously regardless of humidity (use with drain hose).
  3. Timer Mode: Set 1-24 hour operation or delay start.
  4. Fan Only Mode: Circulates air without dehumidifying (press FAN button twice).
  5. Laundry Drying Mode: Runs at high fan speed with continuous operation.

WARNING! Do not operate in freezing temperatures. Ice may form on coils below 41°F.

Maintenance

Regular maintenance ensures optimal performance.

Care & Cleaning

Unplug before cleaning. Clean every 2-4 weeks for best performance.

  1. Filter cleaning: Remove filter, rinse under warm water, air dry completely before reinstalling.
  2. Bucket cleaning: Wash with mild detergent, rinse thoroughly.
  3. Exterior cleaning: Wipe with soft, damp cloth. Do not use abrasive cleaners.
  4. Coil cleaning: Use soft brush to remove dust from rear coils annually.

CAUTION! Never immerse unit in water. Do not use chemical cleaners on filter.

Regulatory Information

UL Listed. CSA Certified. FCC Part 15 Class B compliant. This product contains refrigerant R410A. For proper disposal, contact local waste management authorities. Manufactured for Electrolux Home Products, Inc. For support, visit www.frigidaire.com or contact 1-800-374-4432.

Troubleshooting

SymptomPossible CauseCorrective Action
Unit not runningPower issue/bucket fullCheck power cord; ensure bucket is empty and properly seated.
Little or no water collectionLow humidity/temperatureCheck room humidity; ensure temperature above 41°F.
Water leakageBucket not seated/hose connectionReinstall bucket; check hose connections; ensure unit is level.
Loud noiseFan obstruction/uneven surfaceCheck for obstructions; place on level surface.
Filter light onDirty filterClean filter and press FILTER RESET button.
Ice on coilsLow temperatureTurn off and allow ice to melt; move to warmer area.
Display not workingPower issueCheck outlet; unplug for 5 minutes then restart.

Reset: Unplug for 5 minutes to reset electronic controls.

Service: 1-800-374-4432; www.frigidaire.com

Frigidaire FDR25S1 Dehumidifier Manual © - All Rights Reserved 2025