Frigidaire FDL70S1B Dehumidifier Manual

The Frigidaire FDL70S1B is a 70-pint capacity dehumidifier designed for residential use, featuring automatic humidity control, continuous drainage capability, washable air filter, electronic controls with digital display, auto-restart function, and energy-efficient operation. Suitable for areas up to 4500 cubic feet. Below are key sections for safety, features, installation, setup, operation, maintenance, and troubleshooting.

1. Features at a Glance 2. Installation 3. First-Time Setup 4. Specifications 5. Controls and Settings 6. Operation 7. Maintenance 8. Drainage Options 9. Care & Cleaning 10. Regulatory Information 11. Troubleshooting

Features at a Glance

Key components: Electronic control panel, Digital humidity display, Washable air filter, Continuous drain port, Water collection bucket with handle and full-bucket alert, Casters for mobility.

FeatureDescription
Capacity70 pints per day (at 60°F, 60% RH)
Humidity ControlAutomatic with adjustable set point (35%-85%)
Digital DisplayShows current humidity and settings
Continuous DrainGarden hose adapter for permanent drainage
Air FilterWashable, removable filter
Auto RestartResumes previous settings after power interruption
Bucket Full AlertLight and audible alarm when bucket is full
Timer Function24-hour programmable on/off timer
MobilityFour swivel casters for easy movement
Power Cord6-foot cord with storage wrap

Installation

Unpack and inspect contents. Place on level, stable surface.

  1. Positioning: Place at least 12 inches from walls and furniture for proper airflow.
  2. Check filter: Ensure air filter is properly installed.
  3. Bucket placement: Insert water collection bucket securely.
  4. Power connection: Plug into dedicated 115V AC outlet.
  5. Drainage setup: Attach garden hose to continuous drain port if using permanent drainage.

WARNING! Do not operate in temperatures below 41°F (5°C). Ensure unit is upright for at least 24 hours before first use if transported horizontally.

First-Time Setup

Plug in unit; control panel will illuminate.

  1. Set humidity level: Press HUMIDITY button to select desired level (recommended 45-50%).
  2. Select fan speed: Choose HIGH or LOW using FAN button.
  3. Timer setting: Use TIMER button to program automatic on/off times if desired.
  4. Check operation: Unit should begin dehumidifying when humidity exceeds set point.

CAUTION! Do not block air intake or exhaust. Keep children away from unit.

Specifications

Controls and Settings

Control Panel: POWER button, HUMIDITY adjustment buttons, FAN speed button, TIMER button, FILTER reset indicator, BUCKET FULL indicator.

Display: Shows current room humidity, set humidity, timer settings, and alert indicators.

Humidity Control: Adjust between 35% and 85% in 5% increments. Fan Speed: HIGH for maximum dehumidification, LOW for quiet operation. Timer: Programmable 24-hour on/off schedule. Filter Alert: Illuminates when filter needs cleaning. Bucket Full Alert: Flashing light and beep when bucket needs emptying.

Operation

Normal operation: Unit runs when humidity exceeds set point.

  1. Power on: Press POWER button.
  2. Set desired humidity: Use HUMIDITY buttons.
  3. Select fan speed: Press FAN for HIGH or LOW.
  4. Continuous operation: Set humidity to lowest setting for maximum dehumidification.
  5. Timer use: Press TIMER to set automatic start/stop times.
  6. Bucket monitoring: Empty when FULL indicator activates.

Tip: Close windows and doors for most efficient operation.

Maintenance

Regular maintenance ensures optimal performance.

  1. Clean air filter: Remove and wash every 2 weeks or as needed.
  2. Empty water bucket: When full or before storage.
  3. Clean exterior: Wipe with damp cloth when unit is unplugged.
  4. Check drain hose: Ensure continuous drain hose is clear if used.
  5. Off-season storage: Clean thoroughly, empty all water, store upright in dry location.

WARNING! Always unplug unit before cleaning or maintenance.

Drainage Options

Two drainage methods: Manual bucket or continuous drain.

Bucket Drainage: Unit stops when bucket is full. Empty bucket and replace to resume operation.

Continuous Drainage: Attach standard garden hose (not included) to drain port. Unit will operate continuously without bucket emptying. Ensure hose runs downward without kinks.

Care & Cleaning

Unplug before cleaning. Clean air filter with warm, soapy water. Rinse and dry completely before reinstalling. Wipe exterior with soft, damp cloth. Do not use harsh chemicals or abrasives.

CAUTION! Never immerse unit in water. Do not use gasoline or solvents for cleaning.

Regulatory Information

UL Listed. Meets EPA energy efficiency standards. This product contains refrigerant that must be recovered by certified technicians. For disposal, consult local regulations. Copyright © Frigidaire. For support, visit www.frigidaire.com or contact 1-800-374-4432.

Troubleshooting

SymptomPossible CauseCorrective Action
Unit not runningPower issue/temperatureCheck power connection; ensure room temperature above 41°F.
Low dehumidificationDirty filter/doors openClean air filter; close windows and doors.
Bucket full light onBucket full/drain blockedEmpty bucket; check continuous drain for blockage.
Ice on coilsLow temperatureTurn unit off; allow ice to melt; raise room temperature.
Unusual noiseLoose parts/obstructionCheck for loose panels; ensure unit is level.
Error code displaySensor/system issueUnplug for 10 minutes; restart. If persists, contact service.

Reset: Unplug unit for 10 minutes to reset electronic controls.

Service: 1-800-374-4432; www.frigidaire.com

Frigidaire FDL70S1B Dehumidifier Manual © - All Rights Reserved 2025