Frigidaire FDL70R1 Dehumidifier Manual

The Frigidaire FDL70R1 is a 70-pint dehumidifier designed for residential use, featuring automatic humidity control, continuous drainage capability, a built-in humidistat, washable air filter, automatic restart after power interruption, and a full bucket alert with auto-shutoff. It operates on 115V AC, 60Hz. Below are key sections for safety, features, installation, setup, operation, maintenance, and troubleshooting.

1. Features at a Glance 2. Installation 3. First-Time Setup 4. Specifications 5. Controls and Settings 6. Connecting Drainage 7. Operation Modes 8. Maintenance 9. Care & Cleaning 10. Regulatory Information 11. Troubleshooting

Features at a Glance

Key components: Dehumidifier unit, Water collection bucket, Washable air filter, Continuous drain hose, Power cord, Control panel with digital display.

FeatureDescription
Humidity ControlAutomatic humidistat with adjustable settings (35% - 85% RH)
Water BucketRemovable 70-pint capacity with full indicator and auto-shutoff
Continuous DrainGarden hose connection for continuous water removal
Air FilterWashable filter for improved air quality
Digital DisplayShows current humidity, settings, and alerts
Auto RestartResumes previous settings after power interruption
Timer FunctionProgrammable 24-hour on/off timer
Fan SpeedTwo-speed fan control (High/Low)
Defrost FunctionAutomatic defrost in low temperatures
Carry HandlesIntegrated handles for easy relocation

Installation

Unpack and inspect contents. Place on level, stable surface.

  1. Position unit: Allow at least 12 inches clearance on all sides for proper airflow.
  2. Install filter: Remove filter from packaging and insert into filter compartment.
  3. Check bucket: Ensure water bucket is properly seated and locked in place.
  4. Connect drainage (optional): Attach garden hose to continuous drain port.
  5. Plug into grounded 115V outlet.

WARNING! Do not operate in temperatures below 41°F (5°C). Ensure unit is upright for 24 hours before first use if transported on its side.

First-Time Setup

Plug in unit; control panel will illuminate.

  1. Set desired humidity: Press HUMIDITY button to select target humidity level (recommended 45-50%).
  2. Select fan speed: Press FAN button to choose High or Low speed.
  3. Set timer (optional): Press TIMER to program automatic on/off schedule.
  4. Monitor operation: Display shows current room humidity and operating status.

CAUTION! Do not block air intake or exhaust grilles. Keep unit away from curtains and furniture.

Specifications

Controls and Settings

Control Panel: POWER, HUMIDITY, FAN, TIMER, FILTER RESET. Digital Display: Current humidity, target humidity, timer settings, filter alert, bucket full indicator.

Operation Modes: Continuous mode (runs constantly), Auto mode (maintains set humidity), Timer mode (programmed operation).

Humidity Settings: Adjust in 5% increments from 35% to 85%. Fan Speed: High (maximum dehumidification), Low (quiet operation). Timer: 24-hour programmable in 1-hour increments. Filter Alert: Illuminates when filter needs cleaning (reset with FILTER button).

Connecting Drainage

Continuous drainage option for unattended operation.

  1. Turn off and unplug unit.
  2. Remove bucket and locate drain port on back of unit.
  3. Insert drain hose (¾" garden hose) into port; secure with hose clamp.
  4. Route hose to floor drain, sink, or sump pump.
  5. Replace bucket (unit will not operate without bucket in place).
  6. Plug in and turn on; unit will drain continuously.

Tip: Ensure hose has downward slope without kinks for proper drainage.

Operation Modes

Three operating modes for different needs.

  1. Auto Mode: Unit runs until set humidity is reached, then cycles on/off to maintain.
  2. Continuous Mode: Runs constantly regardless of humidity level.
  3. Timer Mode: Set start/stop times for energy savings.
  4. Defrost Mode: Automatically activates when coil temperature drops below 41°F.
  5. Bucket Full: Unit shuts off automatically; "Bucket Full" indicator illuminates.

WARNING! Empty bucket promptly when full indicator lights. Do not operate without filter installed.

Maintenance

Regular maintenance ensures optimal performance.

Maintenance TaskFrequencyProcedure
Empty Water BucketAs neededRemove, empty, clean with mild detergent, dry completely
Clean Air FilterEvery 2 weeksRemove, wash with warm water, air dry completely
Clean ExteriorMonthlyWipe with damp cloth; never use harsh chemicals
Check Drain HoseMonthlyEnsure no kinks or blockages in continuous drain
Professional ServiceAnnuallyHave qualified technician inspect refrigerant system

Care & Cleaning

Unplug before any maintenance. Use only mild detergent and water for cleaning.

CAUTION! Never immerse unit in water. Do not use gasoline, thinners, or abrasive cleaners. Allow all parts to dry completely before reassembly.

Regulatory Information

UL Listed. FCC Part 15: Class B digital device; complies with interference limits for residential use. Copyright © Frigidaire; trademarks of Electrolux Home Products, Inc. This product contains refrigerant; dispose of according to local regulations. For support, visit www.frigidaire.com or contact 1-800-374-4432.

Troubleshooting

SymptomPossible CauseCorrective Action
Unit not runningPower/BucketCheck power connection; ensure bucket is properly seated; reset GFCI outlet.
Low dehumidificationTemperature/FilterRoom temperature below 65°F; clean air filter; check for blocked airflow.
Water leakageBucket/DrainEnsure bucket properly inserted; check drain hose connection; level unit.
Loud noiseVibration/ObstructionPlace on level surface; check for objects touching unit; clean fan blades.
Display not workingPower/ControlCheck power supply; unplug for 10 minutes then restart; contact service.
Frost on coilsLow temperatureNormal in cold conditions; unit will auto-defrost; raise room temperature.

Reset: Unplug for 10 minutes to reset control system.

Service: 1-800-374-4432; www.frigidaire.com

Frigidaire FDL70R1 Dehumidifier Manual © - All Rights Reserved 2025