Frigidaire FDL60P12 Dehumidifier Manual

The Frigidaire FDL60P12 is a high-capacity 60-pint dehumidifier designed for medium to large rooms, featuring an Energy Star rating, adjustable humidistat, continuous drain option, auto-restart, washable filter, full bucket alert, and quiet operation. Below are key sections for safety, features, installation, setup, operation, maintenance, and troubleshooting.

1. Features at a Glance 2. Installation 3. First-Time Setup 4. Specifications 5. Controls and Settings 6. Connecting Drainage 7. Operation Modes 8. Maintenance 9. Care & Cleaning 10. Regulatory Information 11. Troubleshooting

Features at a Glance

Key components: Front control panel, Water bucket, Washable air filter, Humidistat, Continuous drain port, Casters for mobility.

FeatureDescription
Water BucketRemovable 60-pint capacity with handle and full indicator
Continuous Drain PortFor hose connection to drain water automatically
Adjustable HumidistatSet desired humidity level (35% - 85%)
Washable Air FilterCaptures airborne particles; can be cleaned
Auto RestartResumes previous settings after power interruption
Full Bucket AlertLight and auto-shutoff when bucket is full
Quiet OperationLow-noise design for home use
Energy Star RatedEnergy efficient operation
CastersFour wheels for easy mobility
Power CordStandard 115V, 60Hz plug

Installation

Unpack and inspect contents. Place on level, stable floor.

  1. Positioning: Place at least 12 inches from walls and furniture for proper airflow.
  2. Check filter: Ensure washable filter is properly installed.
  3. Bucket installation: Insert empty water bucket securely until it clicks.
  4. Power connection: Plug into a grounded 115V outlet.

WARNING! Do not use extension cords. Ensure unit is upright before operation.

First-Time Setup

Plug in unit; follow control panel prompts.

  1. Set humidity level: Turn HUMIDISTAT knob to desired setting (e.g., 45-50%).
  2. Select fan speed: Choose HIGH or LOW on FAN SPEED switch.
  3. Test operation: Unit will start when humidity exceeds set point.
  4. Continuous drain (optional): Attach hose to drain port for automatic drainage.

CAUTION! Allow unit to sit upright for 24 hours if transported on its side.

Specifications

Controls and Settings

Front Control Panel: POWER button, HUMIDISTAT knob, FAN SPEED switch (HIGH/LOW), FULL BUCKET indicator light.

Operation: POWER turns unit on/off. HUMIDISTAT sets target humidity. FAN SPEED adjusts airflow. Indicator light illuminates when bucket is full or filter needs cleaning.

Settings: Auto mode (unit cycles based on humidity). Continuous mode (runs constantly when drain hose connected). Bucket mode (collects water in bucket, shuts off when full).

Connecting Drainage

Continuous drain option for unattended operation.

  1. Turn off and unplug unit.
  2. Remove bucket; locate drain port on back.
  3. Insert standard garden hose (¾” inner diameter, not included) into port.
  4. Route hose to floor drain, sink, or outdoors (downward slope required).
  5. Replace bucket; plug in and restart unit.

Tip: Ensure hose is secure and free of kinks to prevent leaks.

Operation Modes

Supports automatic, continuous, and bucket modes.

  1. Automatic: Unit runs until set humidity is reached, then cycles off/on.
  2. Continuous: Runs constantly (use with drain hose).
  3. Bucket: Collects water in bucket; stops when full (light illuminates).
  4. Fan Only: Set fan speed without dehumidifying (for air circulation).
  5. Auto Restart: After power outage, resumes previous settings automatically.

WARNING! Empty bucket promptly to prevent overflow and mildew.

Maintenance

Regular maintenance ensures optimal performance.

Care & Cleaning

Unplug before cleaning. Use mild detergent and soft cloth for exterior. Clean bucket with water and mild soap; rinse thoroughly.

CAUTION! Do not immerse unit in water. Never use gasoline or solvents.

Regulatory Information

UL Listed; meets U.S. safety standards. Energy Star certified. Copyright © Frigidaire. For support, visit www.frigidaire.com or contact 1-800-374-4432.

Troubleshooting

SymptomPossible CauseCorrective Action
Unit not startingPower/humidity settingEnsure plugged in; set humidistat above room humidity.
Little/no water collectionRoom conditions/filterCheck room temp (above 65°F); clean air filter.
Bucket full light onBucket full/not seatedEmpty bucket; ensure bucket is properly inserted.
Unit cycles off quicklyDirty filter/frostClean filter; if cold room, unit may defrost automatically.
Unusual noiseLoose parts/bucketEnsure bucket is secure; check for obstructions near fan.
Water leakageHose connection/bucketCheck hose for kinks; ensure bucket is properly positioned.

Reset: Unplug for 10 minutes, then restart.

Service: 1-800-374-4432; www.frigidaire.com