Frigidaire FDL60K Dehumidifier Manual

The Frigidaire FDL60K is a high-capacity 60-pint dehumidifier designed for residential use in medium to large spaces. It features automatic humidity control, continuous drainage capability, a 24-hour timer, washable air filter, auto-restart function, and low-temperature operation. Below are key sections for safety, features, installation, setup, operation, maintenance, and troubleshooting.

1. Features at a Glance 2. Installation & Placement 3. First-Time Setup 4. Specifications 5. Controls and Settings 6. Operation Modes 7. Maintenance & Cleaning 8. Drainage Options 9. Care & Storage 10. Regulatory Information 11. Troubleshooting

Features at a Glance

Key components: Control panel with digital display, Water tank with full indicator, Continuous drain hose connection, Washable air filter, Carrying handles, Cord storage.

FeatureDescription
Humidity ControlAutomatic humidity sensing with adjustable set point (35%-85%)
Water TankRemovable 60-pint capacity with full indicator and auto shut-off
Continuous DrainGarden hose connection for continuous operation
Timer Function24-hour programmable on/off timer
Air FilterWashable mesh filter for improved air quality
Auto RestartResumes previous settings after power interruption
Low Temp OperationFunctions effectively in temperatures as low as 41°F (5°C)
Control LockPrevents accidental setting changes
Fan SpeedAdjustable fan speed (High/Low)
Display PanelDigital display showing humidity level and settings

Installation & Placement

Unpack and inspect contents. Choose appropriate location.

  1. Clear area: Ensure at least 12 inches of clearance on all sides for proper airflow.
  2. Level surface: Place on firm, level floor to prevent vibration and water spillage.
  3. Check power: Ensure electrical outlet matches unit requirements (120V, 60Hz).
  4. Initial positioning: Keep away from heat sources and direct sunlight.
  5. Drainage setup: Decide between water tank or continuous hose drainage.

WARNING! Do not operate in standing water. Ensure proper ventilation around unit.

First-Time Setup

Plug in unit; allow to stand upright for 24 hours if transported horizontally.

  1. Install filter: Ensure washable air filter is properly seated.
  2. Set humidity: Press HUMIDITY button to select desired level (45-50% recommended).
  3. Select fan speed: Choose HIGH for maximum dehumidification or LOW for quiet operation.
  4. Set timer (optional): Program 24-hour timer for automatic operation.
  5. Check drainage: Install drain hose if using continuous drainage option.

CAUTION! Handle water tank carefully when full to prevent spills.

Specifications

Controls and Settings

Control Panel: POWER, HUMIDITY SET, FAN SPEED, TIMER, FILTER RESET, CONTROL LOCK.

Display Indicators: Current humidity, Set humidity, Timer settings, Filter alert, Full tank indicator, Fan speed.

Humidity Control: Adjust between 35% and 85% in 5% increments. Fan Speed: HIGH for maximum moisture removal, LOW for quiet operation. Timer: Programmable 24-hour on/off schedule. Filter Reset: Press after cleaning filter to reset reminder. Control Lock: Press and hold for 3 seconds to lock/unlock controls.

Operation Modes

Normal Mode: Unit runs until set humidity is reached, then cycles on/off automatically. Continuous Mode: Runs continuously regardless of humidity level (for very damp conditions). Laundry Mode: Higher fan speed for drying laundry in enclosed spaces. Auto Defrost: Automatically defrosts coils in low temperature conditions.

  1. Press POWER to turn unit on.
  2. Set desired humidity level using HUMIDITY buttons.
  3. Select fan speed (HIGH/LOW).
  4. Monitor display for current room humidity.
  5. Empty water tank when FULL indicator lights or use continuous drainage.

Tip: For maximum efficiency, keep doors and windows closed during operation.

Maintenance & Cleaning

Regular maintenance ensures optimal performance and longevity.

  1. Clean air filter: Remove and wash every 2 weeks or as needed. Allow to dry completely before reinstalling.
  2. Empty water tank: Empty regularly to prevent overflow and mineral buildup.
  3. Clean exterior: Wipe with damp cloth. Do not use harsh chemicals.
  4. Check drain hose: Ensure continuous drain hose is clear of obstructions.
  5. Coil cleaning: Have coils professionally cleaned annually for best performance.

WARNING! Always unplug unit before performing any maintenance.

Drainage Options

Water Tank: Standard operation with removable tank. Continuous Drain: Connect 5/8" garden hose to drain port for unattended operation.

For Continuous Drainage:

  1. Remove drain plug from back of unit.
  2. Connect standard garden hose (not included).
  3. Route hose to floor drain or suitable drainage area.
  4. Ensure hose has downward slope without kinks.
  5. Unit will operate continuously without needing to empty tank.

Care & Storage

Off-season storage preparation:

  1. Unplug unit and empty water tank completely.
  2. Clean air filter and allow to dry.
  3. Run unit in fan-only mode for 30 minutes to dry internal components.
  4. Clean exterior with soft, damp cloth.
  5. Coil drain hose and secure with twist tie.
  6. Store upright in dry, protected area.
  7. Cover unit to prevent dust accumulation.

CAUTION! Do not store with water in tank to prevent mold and mildew.

Regulatory Information

UL Listed: Meets UL standard 474. Energy Star: Certified for energy efficiency. FCC Part 15: Class B digital device; complies with interference limits for residential use. Copyright © Frigidaire; trademarks of Electrolux Home Products, Inc. For support, visit www.frigidaire.com or contact 1-800-374-4432. Refrigerant recovery and disposal must be performed by certified technician.

Troubleshooting

SymptomPossible CauseCorrective Action
Unit not runningPower issue/full tankCheck power connection; ensure tank is empty and properly seated.
Poor dehumidificationDirty filter/extreme conditionsClean air filter; ensure room temperature above 41°F; check for air leaks.
Water leakageImproper placement/blocked drainEnsure unit is level; check drain hose for kinks; empty tank regularly.
Loud operationUneven surface/fan issuePlace on level surface; check for obstructions in fan area.
Display not workingPower interruptionUnplug for 10 minutes, then reconnect; check circuit breaker.
Ice on coilsLow temperature operationAuto defrost should activate; if persistent, raise room temperature.
Error codes on displaySensor/system issueConsult manual error code chart; contact service if unresolved.

Reset: Unplug for 10 minutes to reset electronic controls.

Service: 1-800-374-4432; www.frigidaire.com

Frigidaire FDL60K Dehumidifier Manual © - All Rights Reserved 2025