Frigidaire FDL50S1ENG12 Dehumidifier Manual

The Frigidaire FDL50S1ENG12 is a 50-pint dehumidifier designed for medium to large rooms, featuring an Energy Star certification, electronic controls with digital display, continuous drain option, auto-restart, washable filter, and adjustable humidity settings. It operates on 115V/60Hz power and includes features like a full bucket alert, auto-defrost, and 24-hour timer. Below are key sections for safety, features, installation, setup, operation, maintenance, and troubleshooting.

1. Features at a Glance 2. Installation & Placement 3. First-Time Setup 4. Specifications 5. Controls and Settings 6. Operation Modes 7. Maintenance & Cleaning 8. Storage & Winterization 9. Regulatory Information 10. Troubleshooting

Features at a Glance

Key components: Electronic control panel, removable water bucket, continuous drain hose connection, washable air filter, caster wheels for mobility, and digital humidity display.

FeatureDescription
Electronic ControlsDigital display with touchpad for humidity and timer settings
50-Pint CapacityRemoves up to 50 pints of moisture per day (at 80°F/60% RH)
Continuous Drain OptionHose connection for unattended operation
Washable FilterReusable air filter for easy maintenance
Auto-RestartResumes previous settings after power interruption
Auto-DefrostPrevents coil freezing in low temperatures
24-Hour TimerProgram on/off cycles for energy savings
Full Bucket AlertIndicator light and auto-shutoff when bucket is full
Caster WheelsEasy mobility between rooms
Energy Star CertifiedEnergy-efficient operation

Installation & Placement

Unpack and inspect contents. Ensure all parts are present and undamaged.

  1. Placement: Place on a level, firm surface. Allow at least 12 inches of clearance on all sides for proper airflow.
  2. Power Connection: Plug directly into a grounded 115V/60Hz outlet. Do not use extension cords.
  3. Continuous Drain Setup (Optional): Attach 5/8" inner diameter hose to drain port. Ensure hose runs downward to drain.
  4. Bucket Installation: Insert empty water bucket securely until it clicks into place.

WARNING! Do not operate in temperatures below 41°F (5°C). Ensure unit is upright for at least 24 hours before first use if tilted during transport.

First-Time Setup

Plug in the dehumidifier. The control panel will illuminate.

  1. Set Humidity Level: Press the HUMIDITY button to select desired relative humidity (35% to 85% in 5% increments).
  2. Select Fan Speed: Press FAN button to choose between HIGH (faster dehumidification) or LOW (quieter operation).
  3. Timer Programming (Optional): Use TIMER button to set automatic start/stop times.
  4. Continuous Drain Mode: If using hose, ensure bucket is removed or empty. Unit will run continuously until turned off or desired humidity is reached.

CAUTION! Handle the water bucket carefully to avoid spills. Empty bucket before it becomes full to prevent auto-shutoff.

Specifications

Controls and Settings

Control Panel: POWER button, HUMIDITY setting, FAN speed (HIGH/LOW), TIMER, FILTER indicator, FULL BUCKET indicator.

Display Indicators: Current room humidity, set humidity level, timer status, filter alert, bucket full alert.

Humidity Control: Adjust between 35% and 85%. Unit cycles on/off to maintain set level.

Fan Speed: HIGH for maximum moisture removal, LOW for quiet nighttime operation.

Timer: Program up to 24 hours for automatic start or stop.

Auto-Defrost: Automatically activates when coil temperature drops below 41°F; compressor pauses until coil thaws.

Operation Modes

Normal Dehumidification: Set desired humidity; unit runs until level is reached, then cycles.

Continuous Mode: Set humidity to "CONT" (or lowest setting). Unit runs continuously until manually turned off (ideal for continuous drain use).

Laundry Drying Mode: Place in closed room with wet laundry; set to highest fan speed and lowest humidity for faster drying.

  1. Press POWER to turn unit on.
  2. Select humidity level and fan speed.
  3. Monitor water bucket or ensure continuous drain is functioning.
  4. Use TIMER for scheduled operation to save energy.

Tip: Close windows and doors in the room for most efficient operation.

Maintenance & Cleaning

Regular maintenance ensures optimal performance and longevity.

  1. Cleaning the Air Filter: Remove filter every 2 weeks (more often in dusty environments). Wash with warm, soapy water, rinse, and air dry completely before reinstalling.
  2. Emptying the Water Bucket: Remove bucket by lifting handle. Empty water, clean with mild detergent, and dry before replacing.
  3. Cleaning the Exterior: Unplug unit. Wipe cabinet with soft, damp cloth. Do not use abrasive cleaners or solvents.
  4. End-of-Season Cleaning: Run in fan-only mode for a few hours to dry internal components before storage.

WARNING! Always unplug the dehumidifier before performing any maintenance. Do not immerse unit in water.

Storage & Winterization

If not using during cold months, prepare unit for storage.

  1. Unplug dehumidifier.
  2. Empty and clean water bucket. Allow to dry.
  3. Clean air filter and ensure it's dry.
  4. Coil continuous drain hose (if attached) and store with unit.
  5. Store in a dry, covered area. Keep upright.
  6. Cover unit to prevent dust accumulation.

CAUTION! Do not store in temperatures below 41°F (5°C) unless completely drained and dried.

Regulatory Information

This appliance complies with FCC Part 15 Subpart B. It may not cause harmful interference and must accept any interference received. Energy Star qualified. For recycling or disposal, comply with local regulations. Contact local waste management for proper handling of refrigerant. Manufactured for Electrolux Home Products, Inc. For support, visit www.frigidaire.com or contact 1-800-374-4432.

Troubleshooting

SymptomPossible CauseCorrective Action
Dehumidifier does not startNo power, full bucket, timer setEnsure unit is plugged in; empty bucket; check timer settings.
Little or no water collectionLow humidity, cold room, dirty filterCheck room humidity; ensure room temp >41°F; clean filter.
Unit runs but room feels dampRoom too large, doors/windows openUse in smaller enclosed area; close doors and windows.
Loud or unusual noiseUneven placement, loose partsPlace on level surface; check for loose panels or foreign objects.
Water leaking from unitBucket not seated, drain hose leakRemove and reinsert bucket; check hose connections.
FILTER light illuminatedDirty air filterClean filter as per instructions.
Frost on coilsLow room temperatureAuto-defrost should activate; move to warmer area if persistent.

Reset: Unplug for 30 seconds, then plug back in to reset electronic controls.

Service: For technical support, call 1-800-374-4432 or visit www.frigidaire.com.

Frigidaire FDL50S1ENG12 Dehumidifier Manual © - All Rights Reserved 2025