Frigidaire FDL50R1 Dehumidifier Manual

The Frigidaire FDL50R1 is a 50-pint capacity dehumidifier designed for residential use, featuring automatic humidity control, continuous drainage option, washable air filter, auto restart after power interruption, and energy-efficient operation. Ideal for medium to large rooms up to 3000 sq ft. Below are key sections for safety, features, installation, operation, maintenance, and troubleshooting.

1. Features at a Glance 2. Installation & Setup 3. First-Time Operation 4. Specifications 5. Controls and Settings 6. Continuous Drainage Setup 7. Maintenance & Cleaning 8. Energy Saving Tips 9. Regulatory Information 10. Troubleshooting

Features at a Glance

Key components: 50-pint moisture removal capacity, Electronic controls with LED display, Automatic humidity control, Washable air filter, Continuous drainage port, Auto restart, Bucket full indicator, and 24-hour timer.

FeatureDescription
CapacityRemoves up to 50 pints per day (at 80°F, 60% RH)
Humidity ControlAdjustable from 35% to 85% relative humidity
Air FilterWashable mesh filter for improved air quality
Continuous DrainageGarden hose connection for automatic water removal
Auto RestartResumes previous settings after power outage
Bucket Full IndicatorRed light alerts when water bucket needs emptying
Timer24-hour programmable on/off timer
PortabilityBuilt-in handles and caster wheels for easy movement
Energy EfficiencyEnergy Star certified for reduced power consumption
Operating Range41°F to 95°F (5°C to 35°C)

Installation & Setup

Unpack and inspect contents. Place on level, stable surface.

  1. Positioning: Place unit at least 12 inches from walls and furniture for proper airflow.
  2. Power Connection: Plug into dedicated 115V AC, 60Hz grounded outlet.
  3. Bucket Installation: Ensure water bucket is properly seated and locked in place.
  4. Initial Setup: Allow unit to stand upright for 24 hours if transported on its side.

WARNING! Do not use extension cords. Ensure proper ventilation around unit.

First-Time Operation

Power on dehumidifier; follow control panel prompts.

  1. Set Desired Humidity: Press HUMIDITY button to select target level (35%-85%).
  2. Select Fan Speed: Choose LOW or HIGH fan setting for desired air flow.
  3. Timer Programming: Use TIMER button to set automatic on/off schedule.
  4. Monitor Operation: Check LED display for current humidity and settings.

CAUTION! Operate only within specified temperature range (41°F-95°F).

Specifications

Controls and Settings

Control Panel: POWER button, HUMIDITY adjustment, FAN speed (LOW/HIGH), TIMER programming, FILTER reset indicator.

LED Display: Shows current room humidity, target humidity setting, timer status, filter alert, and bucket full indicator.

Humidity Control: Adjust in 5% increments from 35% to 85% RH. Fan Settings: LOW for quiet operation, HIGH for maximum moisture removal. Timer Function: Program on/off cycles in 1-hour increments up to 24 hours. Filter Alert: LED illuminates when air filter needs cleaning (approximately every 250 hours).

Continuous Drainage Setup

For automatic water removal without emptying bucket.

  1. Remove water bucket from unit.
  2. Attach standard garden hose (¾" diameter) to drain port at back of unit.
  3. Route hose to floor drain, sink, or sump pump (ensure downward slope).
  4. Replace bucket (unit will not operate without bucket properly installed).
  5. Unit will now drain continuously while operating.

Tip: Check hose regularly for kinks or blockages to ensure proper drainage.

Maintenance & Cleaning

Regular maintenance ensures optimal performance and longevity.

  1. Air Filter Cleaning: Remove and wash filter every 2-4 weeks with warm water and mild detergent. Allow to dry completely before reinstalling.
  2. Bucket Cleaning: Empty and clean water bucket monthly to prevent mold/mildew.
  3. Exterior Cleaning: Wipe cabinet with soft, damp cloth. Do not use abrasive cleaners.
  4. Coil Inspection: Check evaporator and condenser coils annually for dust buildup.
  5. Off-Season Storage: Drain completely, clean filter and bucket, store in upright position in dry location.

WARNING! Always unplug unit before performing any maintenance.

Energy Saving Tips

Maximize efficiency and reduce operating costs.

Regulatory Information

UL Listed: Meets UL 474 safety standards. Energy Star: Certified for energy efficiency. FCC Compliance: Part 15 Class B digital device. California Proposition 65 Warning: This product contains chemicals known to cause cancer and reproductive harm. Manufactured for Electrolux Home Products, Inc. For support, visit www.frigidaire.com or contact 1-800-374-4432.

Troubleshooting

SymptomPossible CauseCorrective Action
Unit not startingPower issue/bucket fullCheck power connection; ensure bucket is properly installed and not full.
Red light flashingBucket full/filter dirtyEmpty water bucket; clean air filter if filter light is illuminated.
Poor moisture removalTemperature/filter/doorsEnsure room temp is 41°F-95°F; clean filter; close doors and windows.
Unit cycling on/off frequentlyHumidity setting/low loadAdjust humidity setting higher; unit may cycle if moisture load is light.
Water leakageBucket/drain hoseEnsure bucket is properly seated; check drain hose for proper connection and slope.
Unusual noiseVibration/obstructionEnsure unit is level; check for objects touching unit or fan.
Ice on coilsLow temperatureTurn unit off and allow ice to melt; operate only above 41°F.

Reset: Unplug unit for 5 minutes, then restart to reset electronic controls.

Service: 1-800-374-4432; www.frigidaire.com

Frigidaire FDL50R1 Dehumidifier Manual © - All Rights Reserved 2025