The Frigidaire FDL45P13 is a 45-pint capacity dehumidifier designed for medium to large rooms. It features automatic humidity control, continuous drain option, washable air filter, auto-restart after power interruption, full bucket alert with auto-shutoff, and energy-efficient operation. Below are key sections for safety, features, installation, setup, operation, maintenance, and troubleshooting.
Key components: Control panel with digital display, water collection bucket, washable filter, continuous drain hose connection, casters for mobility, and handle.
| Feature | Description |
|---|---|
| Capacity | 45 pints per day (at 60°F, 60% RH) |
| Humidistat | Electronic with adjustable humidity level (35%-85%) |
| Water Bucket | Full bucket alert with auto-shutoff |
| Continuous Drain | Garden hose connection for unattended operation |
| Air Filter | Washable, removable filter |
| Auto Restart | Resumes previous settings after power outage |
| Control Panel | Digital display with touch controls |
| Mobility | Four swivel casters for easy movement |
| Timer | 24-hour programmable on/off timer |
| Energy Efficiency | Energy Star certified |
Unpack and inspect contents. Place on level, stable surface.
WARNING! Do not place near heat sources or in direct sunlight. Ensure proper ventilation around unit.
Plug in unit; follow initial setup procedure.
CAUTION! Allow unit to stand upright for 24 hours if transported on its side.
Control Panel: POWER, HUMIDITY SET, FAN SPEED, TIMER, FILTER RESET.
Display Indicators: Current humidity, set humidity, fan speed, timer, filter alert, bucket full, defrost.
Humidity Control: Adjust between 35% and 85% in 5% increments. Fan Speed: HIGH for maximum moisture removal, LOW for quiet operation. Timer: Program 24-hour schedule for automatic operation. Filter Alert: Lights when filter needs cleaning. Auto Defrost: Automatically activates when coil frosts at low temperatures.
Normal Mode: Continuous operation until set humidity is reached. Auto Mode: Unit cycles on/off to maintain set humidity. Continuous Mode: Runs continuously regardless of humidity level.
Tip: Use AUTO mode for energy-efficient operation in varying conditions.
Regular maintenance ensures optimal performance and longevity.
WARNING! Always unplug unit before performing any maintenance.
Bucket Drain: Manual emptying when full indicator lights. Continuous Drain: Connect standard garden hose (not included) to drain port.
Note: Bucket must be in place even when using continuous drain.
Auto Shutoff: Stops operation when bucket is full. Tip-Over Switch: Turns unit off if tipped over. Overload Protection: Protects compressor from electrical issues. Auto Defrost: Prevents coil freezing in low temperatures.
This appliance complies with Part 15 of the FCC Rules. Operation is subject to the condition that this device does not cause harmful interference. Copyright © Frigidaire. For support, visit www.frigidaire.com or contact 1-800-374-4432. This product contains refrigerant that must be recovered by certified technicians.
| Symptom | Possible Cause | Corrective Action |
|---|---|---|
| Unit not running | Power issue/bucket full | Check power connection; empty bucket; reset circuit breaker. |
| Low moisture removal | Room temperature/filter | Ensure room above 65°F; clean filter; check humidity setting. |
| Unit cycles on/off frequently | Defrost cycle/placement | Normal in low temperatures; ensure proper air circulation. |
| Water leakage | Bucket/hose connection | Ensure bucket properly seated; check hose for leaks/kinks. |
| Loud noise | Uneven surface/fan | Place on level surface; check for foreign objects in fan. |
| Display not working | Power/control issue | Unplug for 10 minutes, then restart; check power source. |
Reset: Unplug unit for 10 minutes to reset electronic controls.
Service: 1-800-374-4432; www.frigidaire.com