Frigidaire FDL45P13 Dehumidifier Manual

The Frigidaire FDL45P13 is a 45-pint capacity dehumidifier designed for medium to large rooms. It features automatic humidity control, continuous drain option, washable air filter, auto-restart after power interruption, full bucket alert with auto-shutoff, and energy-efficient operation. Below are key sections for safety, features, installation, setup, operation, maintenance, and troubleshooting.

1. Features at a Glance 2. Installation & Placement 3. First-Time Setup 4. Specifications 5. Controls and Settings 6. Operation Modes 7. Maintenance & Cleaning 8. Draining Options 9. Safety Features 10. Regulatory Information 11. Troubleshooting

Features at a Glance

Key components: Control panel with digital display, water collection bucket, washable filter, continuous drain hose connection, casters for mobility, and handle.

FeatureDescription
Capacity45 pints per day (at 60°F, 60% RH)
HumidistatElectronic with adjustable humidity level (35%-85%)
Water BucketFull bucket alert with auto-shutoff
Continuous DrainGarden hose connection for unattended operation
Air FilterWashable, removable filter
Auto RestartResumes previous settings after power outage
Control PanelDigital display with touch controls
MobilityFour swivel casters for easy movement
Timer24-hour programmable on/off timer
Energy EfficiencyEnergy Star certified

Installation & Placement

Unpack and inspect contents. Place on level, stable surface.

  1. Remove all packaging materials and tape.
  2. Place unit on level floor with at least 12 inches clearance on all sides.
  3. Ensure proper room temperature (above 65°F for optimal operation).
  4. Check that air filter is properly installed.
  5. Plug into dedicated 115V AC outlet.

WARNING! Do not place near heat sources or in direct sunlight. Ensure proper ventilation around unit.

First-Time Setup

Plug in unit; follow initial setup procedure.

  1. Power on: Press POWER button on control panel.
  2. Set desired humidity: Use UP/DOWN buttons to select humidity level (recommended 45-50%).
  3. Select fan speed: Choose between HIGH and LOW settings.
  4. Set timer (optional): Program 24-hour on/off schedule.
  5. Check bucket: Ensure empty and properly seated.

CAUTION! Allow unit to stand upright for 24 hours if transported on its side.

Specifications

Controls and Settings

Control Panel: POWER, HUMIDITY SET, FAN SPEED, TIMER, FILTER RESET.

Display Indicators: Current humidity, set humidity, fan speed, timer, filter alert, bucket full, defrost.

Humidity Control: Adjust between 35% and 85% in 5% increments. Fan Speed: HIGH for maximum moisture removal, LOW for quiet operation. Timer: Program 24-hour schedule for automatic operation. Filter Alert: Lights when filter needs cleaning. Auto Defrost: Automatically activates when coil frosts at low temperatures.

Operation Modes

Normal Mode: Continuous operation until set humidity is reached. Auto Mode: Unit cycles on/off to maintain set humidity. Continuous Mode: Runs continuously regardless of humidity level.

  1. Select mode using MODE button.
  2. Adjust settings as needed for current conditions.
  3. Monitor display for system status.

Tip: Use AUTO mode for energy-efficient operation in varying conditions.

Maintenance & Cleaning

Regular maintenance ensures optimal performance and longevity.

  1. Clean air filter every 2 weeks: Remove, wash with mild detergent, dry completely.
  2. Empty water bucket regularly or use continuous drain.
  3. Clean exterior with soft, damp cloth; never use harsh chemicals.
  4. Clean condenser coils annually with soft brush.
  5. Check drain hose for obstructions if using continuous drain.

WARNING! Always unplug unit before performing any maintenance.

Draining Options

Bucket Drain: Manual emptying when full indicator lights. Continuous Drain: Connect standard garden hose (not included) to drain port.

  1. For continuous drain: Remove bucket, attach hose to drain port.
  2. Route hose to floor drain or suitable drainage area.
  3. Ensure hose has downward slope without kinks.
  4. Unit will operate continuously until unplugged.

Note: Bucket must be in place even when using continuous drain.

Safety Features

Auto Shutoff: Stops operation when bucket is full. Tip-Over Switch: Turns unit off if tipped over. Overload Protection: Protects compressor from electrical issues. Auto Defrost: Prevents coil freezing in low temperatures.

Regulatory Information

This appliance complies with Part 15 of the FCC Rules. Operation is subject to the condition that this device does not cause harmful interference. Copyright © Frigidaire. For support, visit www.frigidaire.com or contact 1-800-374-4432. This product contains refrigerant that must be recovered by certified technicians.

Troubleshooting

SymptomPossible CauseCorrective Action
Unit not runningPower issue/bucket fullCheck power connection; empty bucket; reset circuit breaker.
Low moisture removalRoom temperature/filterEnsure room above 65°F; clean filter; check humidity setting.
Unit cycles on/off frequentlyDefrost cycle/placementNormal in low temperatures; ensure proper air circulation.
Water leakageBucket/hose connectionEnsure bucket properly seated; check hose for leaks/kinks.
Loud noiseUneven surface/fanPlace on level surface; check for foreign objects in fan.
Display not workingPower/control issueUnplug for 10 minutes, then restart; check power source.

Reset: Unplug unit for 10 minutes to reset electronic controls.

Service: 1-800-374-4432; www.frigidaire.com

Frigidaire FDL45P13 Dehumidifier Manual © - All Rights Reserved 2025