The Frigidaire FDF70S1 is a high-capacity 70-pint dehumidifier designed for residential use, featuring electronic controls, automatic humidistat, continuous drain option, washable air filter, auto-restart, and energy-efficient operation. Ideal for basements, living areas, and other spaces up to 4500 sq. ft. Below are key sections for safety, features, installation, setup, operation, maintenance, and troubleshooting.
Key components: Electronic control panel, 70-pint moisture removal capacity, built-in humidistat, continuous drain hose connection, washable filter, full bucket alert, auto-defrost, and energy-saving mode.
| Feature | Description |
|---|---|
| Moisture Removal | 70 pints per day (at 60°F, 60% RH) |
| Electronic Controls | Digital display with touchpad operation |
| Humidistat | Automatic humidity level control |
| Continuous Drain | Garden hose connection for unattended operation |
| Washable Air Filter | Removable and reusable filter |
| Auto-Restart | Resumes previous settings after power outage |
| Full Bucket Alert | Indicator light and automatic shut-off |
| Auto-Defrost | Prevents coil freezing in low temperatures |
| Energy Saver Mode | Fan runs only when needed to reduce energy use |
| Timer Function | Programmable 2-12 hour on/off timer |
Unpack and inspect contents. Choose appropriate location.
WARNING! Do not place near heat sources or in direct sunlight. Ensure proper ventilation around unit.
Plug in unit; allow to stand upright for 24 hours if transported horizontally.
CAUTION! Handle with care; unit contains refrigerant. Do not tilt or invert during operation.
Control Panel: POWER, HUMIDITY SET, FAN SPEED, TIMER, FILTER RESET, ENERGY SAVER.
Display Indicators: Current humidity, set point, fan speed, timer, filter alert, full bucket, defrost mode.
Humidity Control: Set between 35-85% RH in 5% increments. Fan Speed: HIGH for maximum moisture removal, LOW for quiet operation. Timer: Program 2-12 hours for automatic start/stop. Energy Saver: Fan operates only when compressor runs. Filter Reset: Press after cleaning filter to reset alert.
Normal Mode: Runs continuously until set humidity is reached. Continuous Mode: Runs constantly regardless of humidity (press and hold HUMIDITY for 3 seconds). Laundry Mode: Maximum drying for wet laundry areas. Auto Mode: Unit automatically adjusts fan speed based on humidity level.
Tip: For best efficiency, keep doors and windows closed during operation.
Unplug unit before any maintenance.
WARNING! Never operate without filter. Do not use water above 95°F for cleaning.
Bucket Drainage: Standard method; empty when full (16.9 pint capacity). Continuous Drainage: Connect 5/8" ID garden hose to drain port (hose not included).
CAUTION! Do not elevate drain hose above unit. Check for leaks periodically.
Auto Shut-off: Stops operation when bucket is full or improperly seated. Tip-over Switch: Turns unit off if tipped beyond 45°. Overload Protection: Protects compressor from electrical surges. Auto-Defrost: Prevents ice buildup on coils in low temperatures. Child Lock: Press and hold TIMER and FAN buttons for 3 seconds to lock controls.
UL Listed: Meets UL 474 safety standards. Energy Star: Certified for energy efficiency. EPA Refrigerant: Uses R-410A, an environmentally friendly refrigerant. FCC Part 15: Complies with interference limits. Copyright © Frigidaire; trademarks of Electrolux Home Products, Inc. For support, visit www.frigidaire.com or contact 1-800-374-4432.
| Symptom | Possible Cause | Corrective Action |
|---|---|---|
| Unit not running | Power issue/bucket full | Check power connection; empty bucket; ensure bucket properly seated. |
| Low moisture removal | Room conditions/filter | Check room temperature (above 65°F); clean filter; reduce room size. |
| Unit cycles on/off frequently | Humidistat setting | Adjust humidistat higher; check for air leaks in room. |
| Water leakage | Hose connection/bucket | Check hose for kinks; ensure bucket properly installed; check drain port seal. |
| Loud noise | Vibration/obstruction | Place on level surface; check for objects touching unit; clean fan blades. |
| Display not working | Power/control issue | Unplug for 5 minutes then restart; check circuit breaker. |
| Ice on coils | Low temperature | Auto-defrost should activate; move to warmer area; ensure airflow not blocked. |
Reset: Unplug for 5 minutes to reset electronic controls.
Service: 1-800-374-4432; www.frigidaire.com