Frigidaire FDB70R1ENG11 Dehumidifier Manual

The Frigidaire FDB70R1ENG11 is a 70-pint dehumidifier designed for residential use, featuring an Energy Star rating, digital humidity readout, automatic humidistat control, continuous drain option, washable filter, auto-restart after power interruption, and low-temperature operation capability. Below are key sections for safety, features, installation, setup, operation, maintenance, and troubleshooting.

1. Features at a Glance 2. Installation & Placement 3. First-Time Setup 4. Specifications 5. Controls and Settings 6. Operation Modes 7. Maintenance & Cleaning 8. Storage Instructions 9. Regulatory Information 10. Troubleshooting

Features at a Glance

Key components: Digital control panel, washable air filter, removable water bucket with handle and full-bucket alert, continuous drain hose connection, caster wheels for mobility.

FeatureDescription
Capacity70 pints per day (at 60°F, 60% RH)
HumidistatElectronic, adjustable from 35% to 80% relative humidity
Water BucketRemovable 2.1-gallon bucket with full indicator light
Continuous DrainHose connection for unattended operation
FilterWashable anti-microbial air filter
Auto RestartResumes previous settings after power outage
Low Temp OperationOperates down to 41°F (5°C)
ControlsDigital display, touchpad controls
MobilityFour caster wheels for easy movement
Energy StarMeets Energy Star efficiency standards

Installation & Placement

Unpack and inspect contents. Place on level, stable surface.

  1. Clearance: Allow at least 12-18 inches of clearance on all sides for proper airflow.
  2. Positioning: Place in center of room or area to be dehumidified, away from walls and furniture.
  3. Level Surface: Ensure unit is level to prevent water leakage and ensure proper operation.
  4. Power Connection: Plug directly into grounded 115V AC outlet. Do not use extension cords.
  5. Drain Setup: Choose between bucket collection or connect hose for continuous drainage.

WARNING! Do not operate in temperatures below 41°F (5°C) unless specified for low-temp mode. Ensure proper ventilation.

First-Time Setup

Plug in unit; follow initial setup procedure.

  1. Install filter: Ensure washable filter is properly seated in front grille.
  2. Bucket placement: Insert empty water bucket completely until it clicks into place.
  3. Power on: Press POWER button; unit will beep and display will illuminate.
  4. Set humidity: Press HUMIDITY SET buttons to desired level (recommended 45-50%).
  5. Select fan speed: Choose between HIGH or LOW fan setting.
  6. Continuous drain: If using hose, connect to drain port and route to floor drain or sink.

CAUTION! Handle water bucket carefully when full (approx. 17 lbs). Use both hands.

Specifications

Controls and Settings

Control Panel: POWER, HUMIDITY SET (+/-), FAN SPEED (HIGH/LOW), FILTER ALERT reset, BUCKET FULL indicator.

Display: Current room humidity percentage, set humidity level, fan speed indicator, filter alert, bucket full alert, continuous drain icon.

Humidity Setting: Press +/- to adjust desired humidity level (35-80%). Unit will cycle on/off automatically to maintain set level. Fan Speed: HIGH for maximum moisture removal, LOW for quieter operation. Filter Alert: LED illuminates when filter needs cleaning (approx. every 250 hours). Bucket Full: Red LED and audible beep when bucket needs emptying. Auto Defrost: Automatically activates in low-temperature conditions to prevent coil freezing.

Operation Modes

Normal Dehumidification: Set desired humidity; unit runs until level is reached. Continuous Mode: Set humidity to lowest setting (35%) for continuous operation. Laundry Drying: Place in closed room with wet laundry to accelerate drying. Low Temp Operation: For cool basements or garages; unit may cycle more frequently with auto defrost.

  1. For optimal efficiency, keep doors and windows closed in room being dehumidified.
  2. In high humidity conditions, empty bucket more frequently or use continuous drain.
  3. Use HIGH fan speed for fastest moisture removal, LOW for nighttime or quiet operation.

Tip: For maximum efficiency, clean filter monthly and ensure coils are free of dust.

Maintenance & Cleaning

Unplug unit before any maintenance.

  1. Empty water bucket: Remove and empty when full; clean with mild detergent monthly.
  2. Clean filter: Remove filter every 2-4 weeks; rinse with lukewarm water; air dry completely before reinstalling.
  3. Reset filter alert: After cleaning filter, press and hold FILTER button for 3 seconds.
  4. Exterior cleaning: Wipe cabinet with soft, damp cloth. Do not use abrasive cleaners.
  5. Coil cleaning: Vacuum condenser coils annually to maintain efficiency.
  6. End-of-season: Follow storage instructions if not using for extended period.

WARNING! Never operate without filter installed. Do not immerse unit in water.

Storage Instructions

Prepare unit for seasonal storage or extended non-use.

  1. Unplug unit and allow to sit upright for 24 hours.
  2. Empty and clean water bucket thoroughly.
  3. Clean air filter and allow to dry completely.
  4. Drain any remaining water from continuous drain hose if attached.
  5. Coil unit's power cord neatly and secure with twist tie.
  6. Store in cool, dry place in upright position.
  7. Cover with cloth or plastic to prevent dust accumulation.

CAUTION! Store in area where temperature remains above freezing. Do not store on its side.

Regulatory Information

UL Listed: Meets UL standard 474. FCC Compliance: Class B digital device; complies with Part 15 of FCC rules. Energy Star: Certified to meet energy efficiency guidelines. EPA Refrigerant: Uses R410A refrigerant. For support, visit www.frigidaire.com or contact 1-800-374-4432. This product contains chemicals known to the State of California to cause cancer and birth defects or other reproductive harm.

Troubleshooting

SymptomPossible CauseCorrective Action
Unit not runningNo power/bucket fullCheck power outlet; empty water bucket; ensure filter is clean.
Red bucket light onBucket full/improperly seatedEmpty bucket; ensure bucket is fully inserted until click.
Low moisture removalDirty filter/low temperatureClean filter; check room temp (min 41°F); ensure doors/windows closed.
Filter light onFilter needs cleaningClean filter; press and hold FILTER button for 3 seconds to reset.
Water leakageBucket not seated/unit not levelReinsert bucket; ensure unit is level; check drain hose connection.
Loud noise/vibrationUneven surface/foreign objectPlace on level surface; check for objects near fan; ensure internal components secure.
Frost on coilsLow temperature operationAuto defrost should activate; if persistent, raise room temperature above 65°F.
Display not workingPower issueUnplug for 5 minutes, then reconnect; check circuit breaker.

Reset: Unplug unit for 5 minutes to reset electronic controls.

Service: 1-800-374-4432; www.frigidaire.com