The Frigidaire FDB70R1B is a 70-pint dehumidifier designed for residential use, featuring automatic humidity control, continuous drainage capability, washable filter, electronic controls with digital display, auto-restart function, and energy-efficient operation. Ideal for basements, living areas, and other spaces up to 4500 sq. ft. Below are key sections for safety, features, installation, operation, maintenance, and troubleshooting.
Key components: Electronic control panel, Digital humidity display, Water tank with full indicator, Continuous drain hose connection, Washable air filter, Carrying handles, Caster wheels for mobility.
| Feature | Description |
|---|---|
| Humidity Control | Automatic humidity sensing with adjustable set point (35%-85%) |
| Water Tank | Removable 15.5-pint bucket with full alert and auto-shutoff |
| Continuous Drain | Garden hose connection for unattended operation |
| Air Filter | Washable mesh filter for improved air quality |
| Digital Display | Shows current humidity, set point, and filter alert |
| Auto-Restart | Resumes previous settings after power interruption |
| Turbo Mode | Maximum moisture removal for high humidity conditions |
| 24-Hour Timer | Programmable on/off scheduling |
| Energy Star Certified | Energy-efficient operation |
| Low Temperature Operation | Works effectively down to 41°F (5°C) |
Unpack and inspect contents. Place on level, stable surface.
WARNING! Do not place near heat sources or in direct sunlight. Ensure proper ventilation around unit.
Power on dehumidifier; follow initial setup procedure.
CAUTION! Allow unit to stand upright for 24 hours if transported horizontally.
Control Panel: POWER, MODE, HUMIDITY, TIMER, FILTER RESET.
Display Indicators: Current humidity, Set point, Filter alert, Tank full, Turbo mode, Timer.
Humidity Control: Adjust between 35%-85% in 5% increments. Modes: Normal (standard operation), Turbo (maximum dehumidification), Continuous (runs continuously regardless of humidity). Timer: 24-hour programmable on/off schedule. Filter Alert: Illuminates when filter needs cleaning (reset after cleaning).
Normal Mode: Standard operation with humidity control. Turbo Mode: Maximum moisture removal for high humidity. Continuous Mode: Runs continuously regardless of humidity level.
Tip: For fastest results, close windows and doors during operation.
Regular maintenance ensures optimal performance and longevity.
WARNING! Always unplug unit before cleaning or maintenance.
Two drainage methods: Manual (bucket) or Continuous (hose).
Manual Drainage: Unit stops when bucket is full (indicator lights). Remove bucket, empty, replace. Continuous Drainage: Connect 5/8" ID garden hose to drain port (hose not included). Ensure hose runs downward without kinks. Unit will drain continuously without stopping.
Note: Energy Star certified for efficient operation.
UL Listed: Meets safety standards for household use. Energy Star Certified: Exceeds federal energy efficiency standards. EPA Refrigerant Compliance: Uses R-410A refrigerant. FCC Part 15: Class B digital device. For support, visit www.frigidaire.com or contact 1-800-374-4432. Copyright © Frigidaire. All rights reserved.
| Symptom | Possible Cause | Corrective Action |
|---|---|---|
| Unit not running | Power issue/tank full | Check power connection; empty water tank; reset circuit breaker. |
| Low moisture removal | Dirty filter/cold room | Clean filter; ensure room temperature above 41°F; check humidity setting. |
| Water leakage | Improper placement/tank | Ensure unit is level; check tank seating; inspect drain hose connection. |
| Loud noise | Loose parts/obstruction | Check for loose panels; ensure unit is on solid surface; remove obstructions. |
| Display not working | Power issue | Check power source; unplug for 5 minutes then restart. |
| Filter light on | Dirty filter | Clean filter; press FILTER RESET button for 3 seconds. |
| Ice on coils | Low temperature | Turn unit off; allow ice to melt; increase room temperature above 41°F. |
| Continuous drain not working | Hose issue | Check hose for kinks; ensure downward slope; clean drain port. |
Reset: Unplug for 5 minutes to reset electronic controls.