The Frigidaire FAD704TDB6 is a 70-pint dehumidifier designed for medium to large rooms, featuring electronic controls, a continuous drain option, automatic restart, a 24-hour timer, a washable filter, and a full-bucket alert with auto shut-off. It operates on 115V AC, 60Hz. Below are key sections for safety, features, installation, setup, operation, maintenance, and troubleshooting.

1. Features at a Glance 2. Installation 3. First-Time Setup 4. Specifications 5. Controls and Settings 6. Connecting Drain Hose 7. Operating Modes 8. Maintenance 9. Care & Cleaning 10. Regulatory Information 11. Troubleshooting

Features at a Glance

Key components: Electronic control panel, Water bucket with handle and splash guard, Continuous drain port, Air filter, Casters for mobility.

FeatureDescription
Electronic ControlsDigital display with touchpad for settings
70-Pint CapacityRemoves up to 70 pints per day (at 60°F, 90% RH)
Continuous DrainOption to connect a hose for automatic water removal
Auto RestartResumes previous settings after a power interruption
24-Hour TimerProgram on/off cycles
Washable FilterRemovable air filter for easy cleaning
Full-Bucket AlertIndicator light and auto shut-off when bucket is full
HumidistatSet desired humidity level (35% - 85%)
Fan Speed ControlHigh or Low fan settings
Power Cord StorageBuilt-in wraps for cord management

Installation

Unpack and inspect contents. Place on a level, stable floor.

  1. Position the unit: Allow at least 12-18 inches of clearance on all sides for proper airflow.
  2. Install casters: Attach to the base if not pre-installed.
  3. Check the filter: Ensure the washable filter is properly seated.
  4. Plug into a dedicated 115V AC outlet.

WARNING! Do not operate in temperatures below 41°F (5°C). Ensure the unit is upright for at least 24 hours before first use if tipped during transport.

First-Time Setup

Plug in the dehumidifier; the control panel will illuminate.

  1. Set the humidistat: Press the HUMIDITY button to select your desired level (e.g., 45-50%).
  2. Select fan speed: Press FAN to choose HIGH or LOW.
  3. Set the timer (optional): Use the TIMER buttons to program automatic start/stop.
  4. For continuous drain: Connect a standard garden hose (¾") to the drain port at the back.

CAUTION! Always use the handle to carry the full water bucket. Empty promptly to prevent spills.

Specifications

Controls and Settings

Access all functions via the front electronic control panel.

Control Panel: POWER, HUMIDITY (+/-), FAN (High/Low), TIMER (Set/Up/Down), FILTER ALERT (Reset).

Humidity Control: Set target humidity from 35% to 85%. Fan Speed: HIGH for maximum moisture removal, LOW for quiet operation. Timer: Program the unit to turn ON or OFF after 1-24 hours. Filter Alert: Indicator light reminds you to clean the filter every 250 hours of operation.

Connecting Drain Hose

For continuous operation without emptying the bucket.

  1. Turn off and unplug the dehumidifier.
  2. Remove the bucket from the unit.
  3. Locate the drain port on the back. Remove the rubber plug.
  4. Connect a standard ¾" garden hose (not included). Ensure hose runs downhill to drain.
  5. Replace the bucket. The unit will now drain continuously.

Tip: Ensure the hose is not kinked and the drain path is clear.

Operating Modes

Supports standard dehumidification and customizable settings.

  1. Normal Mode: Set your desired humidity level; unit cycles on/off automatically.
  2. Continuous Mode: Set humidity to its lowest setting (35%) for maximum moisture removal.
  3. Timer Mode: Set the unit to start or stop at a specific time within a 24-hour window.
  4. Auto Defrost: Unit automatically cycles to defrost the coils in low temperatures.
  5. Auto Restart: After a power outage, resumes operation with previous settings.

WARNING! Do not block air intake or exhaust grilles. Operate only within specified temperature range.

Maintenance

Clean Filter: Remove, rinse with warm water, let dry completely, and reinstall every 250 hours or as needed. Reset FILTER alert light after cleaning. Clean Exterior: Wipe with a soft, damp cloth. Empty and Clean Bucket: Regularly empty bucket and clean with mild detergent to prevent mold/mildew.

Care & Cleaning

Always unplug before cleaning. Use only a soft, damp cloth for the cabinet. Do not use harsh chemicals, abrasives, or allow water to enter the electrical components.

CAUTION! Never immerse the unit in water. Store in a dry place when not in use for extended periods.

Regulatory Information

This appliance complies with FCC Part 15 Subpart B. Operation is subject to the condition that this device does not cause harmful interference. Copyright © Frigidaire. Frigidaire is a trademark of AB Electrolux. For support, visit www.frigidaire.com or contact customer service at 1-800-374-4432.

Troubleshooting

SymptomPossible CauseCorrective Action
Unit does not startNo power / Full bucketEnsure plugged in; outlet has power. Empty water bucket.
Red "Bucket Full" light is onBucket full or not seatedEmpty bucket; ensure it is correctly inserted.
Little or no water collectionLow humidity / Cold room / Clogged filterCheck room humidity; ensure temp >41°F; clean air filter.
Unit runs but air feels warmNormal in low humidity / Defrost cycleThis is normal when desired humidity is reached or during defrost.
Unusual noiseLoose parts / Bucker vibrationEnsure unit is on level floor; check if bucket is properly seated.
"Filter" light is onFilter needs cleaningClean the washable filter and press the FILTER button to reset.

Reset: Unplug for 60 seconds, then plug back in to reset electronic controls.

Service: 1-800-374-4432; www.frigidaire.com