Frigidaire FAD704TDB5 Dehumidifier Manual

The Frigidaire FAD704TDB5 is a 70-pint capacity dehumidifier designed for medium to large rooms, featuring automatic humidity control, continuous drain option, washable air filter, electronic controls with digital display, 24-hour timer, auto-restart after power interruption, and Energy Star certification. Below are key sections for safety, features, installation, setup, operation, maintenance, and troubleshooting.

1. Features at a Glance 2. Installation & Placement 3. First-Time Setup 4. Specifications 5. Controls and Settings 6. Operation Modes 7. Maintenance & Cleaning 8. Storage Instructions 9. Regulatory Information 10. Troubleshooting

Features at a Glance

Key components: Electronic control panel, Digital humidity display, Washable air filter, Bucket with full indicator, Continuous drain hose connection, Casters for mobility.

FeatureDescription
Capacity70 pints per day (at 60°F, 90% RH)
Humidity ControlAutomatic with adjustable set point (35%-85%)
Digital DisplayShows current humidity, settings, and alerts
Continuous DrainOption for hose connection (hose not included)
Air FilterWashable, removable filter for air quality
Timer24-hour programmable on/off timer
Auto RestartResumes previous settings after power outage
Bucket Full AlertLight and audible alarm when bucket is full
Energy StarCertified for energy efficiency
MobilityFour swivel casters for easy movement

Installation & Placement

Unpack and inspect contents. Place on level, stable surface.

  1. Choose location: Place in center of room, away from walls/furniture (minimum 12-18 inches clearance).
  2. Check airflow: Ensure air intake and exhaust are unobstructed.
  3. Level unit: Use adjustable feet if necessary to prevent vibration.
  4. Connect drain hose (optional): Attach to drain port and route to floor drain or sink.
  5. Plug into grounded 115V AC outlet.

WARNING! Do not use extension cords. Ensure outlet is dedicated and properly grounded. Keep away from water sources.

First-Time Setup

Power on dehumidifier; follow initial setup steps.

  1. Set humidity level: Press HUMIDITY button to desired set point (recommended 45-50%).
  2. Select fan speed: Choose LOW for quiet operation or HIGH for maximum moisture removal.
  3. Set timer (optional): Use TIMER button to program automatic on/off cycles.
  4. Check bucket: Ensure bucket is properly seated and empty.
  5. Run test cycle: Allow unit to run for 15 minutes to verify operation.

CAUTION! Do not operate in temperatures below 41°F (5°C). Frost may form on coils.

Specifications

Controls and Settings

Control Panel: POWER, HUMIDITY SET, FAN SPEED (LOW/HIGH), TIMER, FILTER ALERT RESET.

Display Indicators: Current humidity, Set point, Timer status, Filter alert, Bucket full, Fan speed.

Humidity Control: Adjust between 35%-85% in 5% increments. Fan Speed: LOW for quiet operation, HIGH for maximum dehumidification. Timer: Program on/off cycles in 1-hour increments up to 24 hours. Auto Defrost: Automatically activates when coil temperature drops below 41°F. Continuous Drain: Connect 5/8" ID hose to drain port (hose not included).

Operation Modes

Normal Mode: Runs continuously until set humidity is reached. Timer Mode: Automatically turns unit on/off at set times. Continuous Mode: Runs continuously regardless of humidity (for very damp areas).

  1. Press POWER to turn unit on.
  2. Set desired humidity level using HUMIDITY buttons.
  3. Select fan speed (LOW or HIGH).
  4. For continuous operation, set humidity to lowest setting (35%).
  5. Monitor water collection in bucket or drain hose.

Tip: Close windows and doors for most efficient operation. Ideal humidity range is 45-50%.

Maintenance & Cleaning

Regular maintenance ensures optimal performance and longevity.

  1. Clean air filter: Remove and wash every 2-4 weeks with warm, soapy water. Dry completely before reinstalling.
  2. Empty water bucket: When full indicator lights, turn unit off, remove bucket, and empty. Clean with mild detergent monthly.
  3. Clean exterior: Wipe with soft, damp cloth. Do not use abrasive cleaners.
  4. Check drain hose: Ensure continuous drain hose is clear of obstructions.
  5. Coil cleaning: Have coils professionally cleaned annually for best efficiency.

WARNING! Always unplug unit before cleaning. Never immerse in water. Do not use harsh chemicals.

Storage Instructions

When not in use for extended periods:

  1. Unplug unit and allow to dry completely for 24 hours.
  2. Clean air filter and bucket thoroughly.
  3. Empty all water from bucket and drain system.
  4. Coil storage: Run fan-only mode for 1 hour to dry coils completely.
  5. Store in upright position in dry, covered area.
  6. Cover unit to prevent dust accumulation.

CAUTION! Store in temperature-controlled environment. Do not store with water in bucket.

Regulatory Information

UL Listed: Meets UL standard 474. Energy Star: Certified for energy efficiency. FCC Part 15: Class B digital device; complies with interference limits. California Proposition 65 Warning: This product contains chemicals known to cause cancer and birth defects. For support, visit www.frigidaire.com or contact 1-800-374-4432. Manufactured for Electrolux Home Products, Inc.

Troubleshooting

SymptomPossible CauseCorrective Action
Unit not runningPower issue/bucket fullCheck power connection; empty bucket; ensure bucket properly seated.
Poor dehumidificationRoom too cold/filter dirtyEnsure room temperature above 41°F; clean air filter; check for air obstructions.
Water leakingBucket not seated/hose connectionEnsure bucket properly installed; check drain hose for kinks/leaks.
Loud noise/vibrationUneven surface/loose partsPlace on level surface; check for loose panels or foreign objects inside.
Display not workingPower interruptionUnplug for 5 minutes, then reconnect; check circuit breaker.
Frost on coilsLow temperatureTurn unit off and allow to defrost; increase room temperature above 41°F.
Filter light onDirty filterClean air filter; press FILTER RESET button for 3 seconds.

Reset: Unplug for 5 minutes to reset electronic controls.

Service: 1-800-374-4432; www.frigidaire.com

Frigidaire FAD704TDB5 Dehumidifier Manual © - All Rights Reserved 2025