The Frigidaire FAD704DUD14 is a 70-pint capacity dehumidifier designed for residential use. It features electronic controls with a digital display, automatic humidity control, continuous drain option, washable filter, full bucket alert with auto shut-off, and a 24-hour timer. Below are key sections for safety, features, installation, setup, operation, maintenance, and troubleshooting.
Key components: Electronic control panel, water collection bucket, washable air filter, continuous drain port, casters for mobility.
| Feature | Description |
|---|---|
| Capacity | 70 pints per day (at 60°F, 90% RH) |
| Control Panel | Digital display with touch controls |
| Humidity Control | Auto humidity set from 35% to 85% |
| Timer | 24-hour on/off programmable timer |
| Bucket Full Alert | Indicator light and auto shut-off |
| Continuous Drain | Option for hose connection |
| Filter | Washable anti-microbial air filter |
| Mobility | Four swivel casters |
| Power Cord | 6-foot cord with plug |
| Dimensions | Approx. 15.4" W x 11.4" D x 24.3" H |
Unpack and inspect contents. Place on level, stable surface.
WARNING! Do not use extension cords. Ensure outlet is properly grounded.
Plug in unit; control panel will illuminate.
CAUTION! Operate only in temperatures between 41°F and 90°F.
Control Panel: POWER button, HUMIDITY SET, FAN speed, TIMER, FILTER ALERT reset.
Display Indicators: Current humidity, set humidity, fan speed, timer status, bucket full, filter alert.
Humidity Control: Set between 35% and 85%. Unit cycles automatically to maintain set point. Fan Speed: HIGH for maximum moisture removal, LOW for quiet operation. Timer: Program unit to turn on/off up to 24 hours in advance. Filter Alert: Light illuminates when filter needs cleaning (approx. every 250 hours).
For continuous operation without emptying bucket.
Tip: Ensure hose has a downward slope to prevent water backup.
Normal Mode: Set desired humidity, fan speed. Unit runs until humidity is reached, then cycles. Continuous Mode: Set humidity to lowest setting (35%) for continuous operation. Timer Mode: Set to turn on/off at specific times. Auto Restart: After power outage, unit resumes previous settings automatically.
WARNING! Do not operate without filter or bucket properly installed.
Filter Cleaning: Clean every 2-4 weeks or when FILTER light illuminates.
Bucket Cleaning: Empty and clean bucket with mild detergent monthly.
Unplug before any cleaning. Wipe exterior with soft, damp cloth. Do not use abrasive cleaners. Clean air intake and outlet grilles with vacuum brush attachment.
CAUTION! Never immerse unit in water. Do not use near flammable vapors.
This appliance complies with FCC Part 15. UL listed. For your safety and to ensure performance, all repairs should be done by an authorized service technician. Copyright © Frigidaire. For support, visit www.frigidaire.com or contact 1-800-374-4432.
| Symptom | Possible Cause | Corrective Action |
|---|---|---|
| Unit not starting | No power, bucket not in place | Check plug, outlet; ensure bucket is properly seated. |
| Low moisture removal | Dirty filter, low temperature | Clean filter; ensure room temp above 41°F. |
| Bucket full light on (bucket empty) | Float stuck, sensor issue | Check bucket alignment; clean float area. |
| Unusual noise | Loose parts, fan obstruction | Ensure unit is level; check for debris near fan. |
| Error code on display | Sensor fault, system error | Unplug for 10 minutes, then restart. If persists, call service. |
Reset: Unplug for 10 minutes to reset electronic controls.
Service: 1-800-374-4432; www.frigidaire.com