The Frigidaire CAD704DUL13 is a 70-pint capacity dehumidifier designed for residential use. It features electronic controls with a digital display, automatic humidity sensing, continuous drain capability, a washable filter, and a built-in carrying handle. Below are key sections for safety, features, installation, setup, operation, maintenance, and troubleshooting.
Key components: Electronic control panel, Digital humidity display, 70-pint water tank, Washable air filter, Continuous drain port, Automatic shut-off, Carrying handles.
| Feature | Description |
|---|---|
| Capacity | 70 pints per day (at 60°F, 90% RH) |
| Control Panel | Electronic touch controls with LED display |
| Humidistat | Adjustable from 35% to 85% relative humidity |
| Water Tank | Full tank indicator and automatic shut-off |
| Continuous Drain | Garden hose adapter included for permanent drainage |
| Air Filter | Washable, removable filter for easy cleaning |
| Auto Restart | Resumes previous settings after power interruption |
| Timer Function | 24-hour programmable on/off timer |
| Carrying Handles | Integrated handles for easy relocation |
| Power Cord | 6-foot cord with storage wrap |
Unpack and inspect contents. Place on level, stable surface.
WARNING! Do not place near heat sources or in direct sunlight. Ensure room temperature is between 41°F and 95°F for optimal operation.
Plug in unit; allow to stand upright for 24 hours if transported horizontally.
CAUTION! Handle water tank carefully when full; empty before moving unit.
Control Panel: POWER, HUMIDITY (+/-), FAN SPEED (HIGH/LOW), TIMER, FILTER RESET.
Display Indicators: Current humidity, Set humidity, Full tank, Filter clean, Timer active.
Humidity Setting: Adjust between 35-85% RH. Fan Speed: HIGH for maximum moisture removal, LOW for quiet operation. Timer: Program unit to turn on/off at specific times (1-24 hours). Filter Reset: Press after cleaning filter to reset reminder light. Continuous Mode: Fan runs continuously regardless of humidity level.
Automatic: Unit cycles on/off to maintain set humidity level. Continuous: Fan runs constantly for maximum air circulation. Timer: Set automatic start/stop times for energy savings.
Tip: Close windows and doors in room being dehumidified for best results.
Unplug unit before performing any maintenance.
WARNING! Never operate without filter installed. Do not immerse unit in water.
Prepare unit for seasonal storage when not in use for extended periods.
CAUTION! Do not store with water in tank. Protect from freezing temperatures.
UL Listed: Meets UL standard 474 for dehumidifiers. Energy Star: Certified for energy efficiency. EPA Refrigerant: Uses R410A, an environmentally friendly refrigerant. Copyright © Frigidaire; trademarks of Electrolux Home Products, Inc. For support, visit www.frigidaire.com or contact 1-800-374-4432.
| Symptom | Possible Cause | Corrective Action |
|---|---|---|
| Unit not starting | Power issue/full tank | Check power connection; ensure tank is empty and properly seated. |
| Low moisture removal | Room conditions/filter | Check room temperature (41-95°F); clean filter; close windows/doors. |
| Water leaking | Tank/drain connection | Ensure tank is properly positioned; check drain hose for kinks/leaks. |
| Loud operation | Uneven surface/fan | Place on level surface; check for obstructions in fan area. |
| Ice on coils | Low temperature | Room temperature below 41°F; turn off and allow to thaw; move to warmer area. |
| Filter light on | Dirty filter | Clean filter as instructed; press FILTER RESET button. |
| Display not working | Power interruption | Unplug for 5 minutes, then reconnect; check circuit breaker. |
Reset: Unplug unit for 5 minutes to reset electronic controls.
Service: 1-800-374-4432; www.frigidaire.com