The Frigidaire CAD504DUL13 is a 50-pint capacity dehumidifier designed for residential use, featuring electronic controls, auto-restart, continuous drain capability, washable filter, and a built-in humidistat for precise moisture control. It operates on 115V/60Hz power and is suitable for areas up to 3000 sq. ft. Below are key sections covering safety, features, installation, operation, maintenance, and troubleshooting.

1. Features at a Glance 2. Installation & Placement 3. First-Time Setup 4. Specifications 5. Controls and Settings 6. Operation Modes 7. Maintenance & Cleaning 8. Drainage Options 9. Care & Storage 10. Regulatory Information 11. Troubleshooting

Features at a Glance

Key components: Electronic control panel, 50-pint water bucket with full-bucket alert, continuous drain hose connection, washable air filter, built-in humidistat, and auto-restart function.

FeatureDescription
Capacity50 pints per day (at 60°F, 60% RH)
Control PanelElectronic touch controls with LED display
HumidistatAdjustable from 35% to 85% relative humidity
Water BucketRemovable with handle and full-bucket indicator
Continuous DrainGarden hose connection for unattended operation
Air FilterWashable mesh filter for easy maintenance
Auto RestartResumes previous settings after power interruption
Turbo ModeMaximum moisture removal for high humidity
Timer24-hour programmable on/off timer
Power115V, 60Hz, 5.0 Amps

Installation & Placement

Unpack and inspect contents. Choose appropriate location for optimal performance.

  1. Clearance: Place at least 12 inches from walls and furniture for proper airflow.
  2. Level surface: Ensure unit is on a flat, stable surface to prevent tipping.
  3. Temperature range: Operate between 41°F (5°C) and 95°F (35°C).
  4. Power connection: Plug directly into grounded 115V outlet; avoid extension cords.

WARNING! Do not operate in temperatures below 41°F (5°C) to prevent coil freezing. Ensure proper ventilation around unit.

First-Time Setup

Power on dehumidifier; configure initial settings.

  1. Install filter: Ensure washable filter is properly seated in front grille.
  2. Set humidistat: Press HUMIDITY button to set desired level (recommended 45-50%).
  3. Select mode: Choose between Normal, Turbo, or Timer mode based on needs.
  4. Check drainage: Install bucket or connect drain hose for continuous operation.

CAUTION! Handle water bucket carefully when full; empty promptly when indicator light illuminates.

Specifications

Controls and Settings

Access all functions via electronic control panel. Front Panel: POWER, MODE, HUMIDITY, TIMER, FILTER RESET.

Display Indicators: Current humidity, set point, bucket full, filter clean, turbo mode, timer status.

Humidity Control: Adjust from 35% to 85% RH in 5% increments. Mode Selection: NORMAL (standard operation), TURBO (maximum dehumidification), TIMER (programmable on/off). Timer: Set 1-24 hours for automatic start/stop. Filter Alert: LED illuminates when filter needs cleaning (reset with FILTER button).

Operation Modes

Normal Mode: Standard operation at set humidity level. Turbo Mode: Runs compressor and fan at maximum for rapid moisture removal. Timer Mode: Program unit to turn on/off at specific times.

  1. Press POWER to turn unit on.
  2. Press MODE to cycle through Normal, Turbo, and Timer.
  3. In Timer mode, use +/- buttons to set hours (1-24).
  4. Press HUMIDITY to set desired humidity level.
  5. Unit will cycle automatically to maintain set humidity.

Tip: Use Turbo mode initially in very damp spaces, then switch to Normal for maintenance.

Maintenance & Cleaning

Regular maintenance ensures optimal performance and longevity.

  1. Clean filter: Remove and wash with warm, soapy water every 2-4 weeks.
  2. Empty bucket: Remove and empty water bucket when full indicator lights.
  3. Clean exterior: Wipe with damp cloth; do not use harsh chemicals.
  4. Check drain hose: Ensure continuous drain connection is clear if used.
  5. Off-season storage: Clean thoroughly and store in dry location.

WARNING! Always unplug unit before cleaning. Never immerse in water or use abrasive cleaners.

Drainage Options

Bucket Drainage: Standard method using removable bucket. Continuous Drainage: Connect 5/8" ID garden hose to drain port for unattended operation.

Care & Storage

For seasonal storage: Empty and clean bucket, clean filter, coil, and housing. Wrap cord and store in upright position in dry area.

CAUTION! Do not store with water in bucket. Allow all components to dry completely before storage.

Regulatory Information

UL Listed: Meets UL 474 safety standards. Energy Star: Certified for energy efficiency. EPA: Compliant with refrigerant regulations. Copyright © Frigidaire; trademarks of Electrolux Home Products, Inc. For support, visit www.frigidaire.com or contact 1-800-374-4432.

Troubleshooting

SymptomPossible CauseCorrective Action
Unit not runningPower/bucket fullCheck power connection; empty bucket; ensure filter is clean.
Poor dehumidificationTemperature/filterEnsure room temp above 41°F; clean filter; check for air blockage.
Water leakageBucket/drain hoseEnsure bucket properly seated; check drain hose connection.
Loud noiseVibration/obstructionPlace on level surface; check for objects touching unit.
Display not workingPower/control issueUnplug for 5 minutes then restart; check outlet power.

Reset: Unplug for 5 minutes to reset electronic controls.

Service: 1-800-374-4432; www.frigidaire.com