Frigidaire CAD301NUD13 Dehumidifier Manual

The Frigidaire CAD301NUD13 is a 30-pint capacity dehumidifier designed for medium-sized rooms up to 1500 sq. ft. It features an Energy Star certification, adjustable humidity control (35%-85%), continuous drain option, automatic shut-off when tank is full, washable air filter, 24-hour timer, and easy-roll casters for mobility. Below are key sections for safety, features, installation, setup, operation, maintenance, and troubleshooting.

1. Features at a Glance 2. Installation & Placement 3. First-Time Setup 4. Specifications 5. Controls and Settings 6. Operation Modes 7. Maintenance & Cleaning 8. Storage Instructions 9. Regulatory Information 10. Troubleshooting

Features at a Glance

Key components: Control panel with digital display, 1.8-gallon water tank, washable filter, continuous drain hose connection, casters, and carrying handle.

FeatureDescription
Capacity30 pints per day (at 80°F, 60% RH)
Humidity ControlAdjustable from 35% to 85% relative humidity
Water Tank1.8-gallon removable bucket with full-tank indicator and auto shut-off
Continuous DrainHose connection for unattended operation
Air FilterWashable mesh filter for improved air quality
Timer24-hour programmable on/off timer
MobilityFour easy-roll casters and side carrying handle
Energy EfficiencyEnergy Star certified for lower power consumption
DisplayDigital display showing humidity level and settings
ControlsElectronic touch controls for humidity, fan speed, and timer

Installation & Placement

Unpack and inspect contents. Place on level, stable surface.

  1. Choose location: Place in center of room or area with high humidity, away from walls and furniture for proper airflow.
  2. Check clearance: Ensure at least 12 inches of space on all sides, especially air intake and exhaust.
  3. Level unit: Use a level to ensure proper operation; uneven surfaces may affect performance.
  4. Connect drain hose (optional): Attach standard garden hose to continuous drain port for extended operation.
  5. Plug into grounded 120V AC outlet.

WARNING! Do not place near heat sources or in direct sunlight. Ensure the unit is upright for at least 24 hours before first use if transported on its side.

First-Time Setup

Power on dehumidifier; follow initial setup steps.

  1. Insert water tank: Ensure bucket is fully seated; unit will not operate if tank is missing or improperly installed.
  2. Set desired humidity: Press HUMIDITY button to select between 35% and 85% (45%-50% recommended for comfort).
  3. Select fan speed: Choose between HIGH (faster dehumidification) or LOW (quieter operation).
  4. Program timer (optional): Use TIMER button to set automatic start/stop times.
  5. Monitor operation: Check display for current room humidity and settings.

CAUTION! Handle water tank with care to avoid spills. Always turn off and unplug before servicing.

Specifications

Controls and Settings

Access all functions via the electronic control panel on top of unit.

Control Panel: POWER, HUMIDITY (+/-), FAN SPEED (HIGH/LOW), TIMER, FILTER RESET indicator.

Display Icons: Current humidity %, set humidity %, fan speed, timer, full tank alert, filter clean reminder.

Humidity Setting: Adjust in 5% increments. Unit cycles on/off to maintain set level.

Fan Speed: HIGH for maximum moisture removal, LOW for quiet nighttime operation.

Timer: Program up to 24 hours for automatic start or stop.

Auto Restart: After power outage, unit resumes previous settings automatically.

Operation Modes

Normal Mode: Set desired humidity; unit runs until level is reached then cycles.

  1. Continuous Mode: Set humidity to lowest setting (35%) for maximum dehumidification.
  2. Timer Mode: Set unit to turn on/off at specific times for energy savings.
  3. Laundry Mode: Place in closed room with wet laundry to accelerate drying.
  4. Auto Defrost: Built-in feature prevents coil freezing in low temperatures (below 65°F).

Tip: For best efficiency, keep doors and windows closed while operating.

Maintenance & Cleaning

Regular maintenance ensures optimal performance and longevity.

  1. Empty water tank: When FULL indicator lights, turn off, remove tank, empty, and replace.
  2. Clean air filter: Every 2-4 weeks, remove filter, wash with mild detergent, rinse, dry completely before reinstalling.
  3. Reset filter indicator: After cleaning filter, press and hold FILTER button for 3 seconds.
  4. Clean exterior: Wipe with soft, damp cloth; never use harsh chemicals or abrasives.
  5. Clean water tank: Monthly, wash with mild soap and water to prevent mold/mildew.
  6. End-of-season cleaning: Follow storage instructions for extended non-use.

WARNING! Always unplug before cleaning. Do not immerse unit in water.

Storage Instructions

For seasonal storage or extended non-use:

  1. Turn off and unplug unit.
  2. Empty and clean water tank thoroughly; allow to dry.
  3. Clean air filter and ensure it's completely dry.
  4. Run unit in FAN ONLY mode for 30 minutes to dry internal components.
  5. Coil and secure power cord.
  6. Store upright in cool, dry place; cover to prevent dust accumulation.

CAUTION! Store in temperature-controlled environment. Do not place heavy objects on top.

Regulatory Information

This appliance complies with Part 15 of FCC Rules. Operation is subject to the condition that it does not cause harmful interference. Copyright © Frigidaire; trademarks of Electrolux Home Products, Inc. For support, visit www.frigidaire.com or contact 1-800-374-4432. Energy Star is a registered trademark of the U.S. Environmental Protection Agency.

Troubleshooting

SymptomPossible CauseCorrective Action
Unit not turning onNo powerCheck outlet; ensure plug is secure; test outlet with another device.
Not collecting waterRoom humidity below set pointLower humidity setting; ensure room temp above 41°F.
Full tank light on but tank not fullFloat stuck or misalignedRemove tank, check float moves freely; reinstall properly.
Loud or unusual noiseLoose parts or debrisEnsure unit is level; check for objects near fan; clean filter.
Ice on coilsLow temperature operationAuto defrost should activate; move to warmer area if below 41°F.
Reduced airflowDirty filterClean air filter as per instructions.
Error code on displaySensor or system faultUnplug for 5 minutes, then restart. If persists, contact service.

Reset: Unplug for 5 minutes to reset electronic controls.

Service: 1-800-374-4432; www.frigidaire.com