Frigidaire 327000009 Dehumidifier Manual

The Frigidaire 327000009 is a high-capacity dehumidifier designed to remove excess moisture from the air, preventing mold, mildew, and creating a more comfortable environment. It features adjustable humidity control, continuous drainage option, auto-restart, washable air filter, and a full tank alert with automatic shut-off. Below are key sections for safety, features, installation, setup, operation, maintenance, and troubleshooting.

1. Features at a Glance 2. Installation & Placement 3. First-Time Setup 4. Specifications 5. Controls and Settings 6. Operation Modes 7. Maintenance & Cleaning 8. Drainage Options 9. Care & Storage 10. Regulatory Information 11. Troubleshooting

Features at a Glance

Key components: Control Panel, Water Tank, Air Filter, Drain Hose Connector, Casters for mobility, and Humidity Sensor.

FeatureDescription
Humidity ControlAdjustable digital humidistat with LED display
Water TankRemovable bucket with full-tank indicator and auto shut-off
Continuous DrainageHose connection for unattended operation
Air FilterWashable filter to clean incoming air
Auto RestartResumes previous settings after a power interruption
Turbo ModeMaximum moisture removal for high humidity conditions
Control LockPrevents accidental setting changes
Filter AlertIndicator light reminds you to clean the filter
24-Hour TimerProgram on/off cycles for energy efficiency
Casters & HandlesEasy mobility between rooms

Installation & Placement

Unpack and inspect contents. Place on a level, stable surface.

  1. Choose Location: Place in center of room, at least 12 inches from walls and furniture for proper airflow.
  2. Check Airflow: Ensure air intake and exhaust grilles are unobstructed.
  3. Set Up Drainage: For continuous use, attach drain hose to connector and route to floor drain or sink.
  4. Plug into Outlet: Use a dedicated 120V AC, 15-amp grounded outlet.

WARNING! Do not use in temperatures below 41°F (5°C). Ensure unit is upright before operation.

First-Time Setup

Power on dehumidifier; follow initial setup steps.

  1. Install Water Tank: Slide bucket into place until it clicks.
  2. Set Humidity Level: Press HUMIDITY button to select desired level (35%-85%).
  3. Select Fan Speed: Choose LOW for quiet operation or HIGH/TURBO for maximum dehumidification.
  4. Set Timer (Optional): Use TIMER button to program automatic start/stop times.

CAUTION! Handle water tank with care to avoid spills. Do not operate without filter installed.

Specifications

Controls and Settings

Access controls via front panel buttons and digital display.

Control Panel: POWER, HUMIDITY SET, FAN SPEED (LOW/HIGH/TURBO), TIMER, FILTER RESET, CONTROL LOCK.

Display Indicators: Current Humidity, Set Humidity, Full Tank Alert, Filter Clean, Timer Active, Control Lock. Settings: Humidity Level (35%-85% in 5% increments), Fan Speed (affects noise and dehumidification rate), Timer (1-24 hours), Auto Defrost (activates automatically in cold conditions).

Operation Modes

Normal Mode: Set desired humidity; unit cycles on/off automatically. Continuous Mode: Set humidity to lowest setting for constant operation. Turbo Mode: Maximum fan speed for rapid moisture removal. Timer Mode: Program unit to turn on/off at specific times.

  1. Press POWER to turn unit on.
  2. Set target humidity using HUMIDITY buttons.
  3. Select fan speed for desired airflow and noise level.
  4. Monitor display for current room humidity and alerts.

Tip: For energy savings, set humidity to 50-55% for most home environments.

Maintenance & Cleaning

Regular maintenance ensures optimal performance and longevity.

  1. Clean Air Filter: Remove and wash filter every 2 weeks in warm, soapy water. Rinse and dry completely before reinstalling.
  2. Empty Water Tank: When FULL indicator lights, turn unit off, remove tank, and empty. Replace securely.
  3. Clean Exterior: Wipe cabinet with soft, damp cloth. Do not use harsh chemicals.
  4. Check Drain Hose: Ensure continuous drain hose is clear of obstructions and properly routed.
  5. Off-Season Storage: Follow proper storage procedures when not in use for extended periods.

WARNING! Always unplug unit before cleaning or maintenance. Never immerse in water.

Drainage Options

Bucket Drainage: Use removable tank; empty when full. Continuous Drainage: Attach 5/8" ID hose (not included) to drain port for automatic water removal to floor drain or sink.

Care & Storage

For seasonal storage: Empty and clean tank, clean filter, wrap cord, cover unit, and store upright in dry location.

CAUTION! Do not store with water in tank. Protect from dust and extreme temperatures.

Regulatory Information

UL Listed; complies with U.S. safety standards. Energy Star certified for energy efficiency. Copyright © Frigidaire; trademarks of Electrolux Home Products, Inc. For support, visit www.frigidaire.com or contact 1-800-374-4432.

Troubleshooting

SymptomPossible CauseCorrective Action
Unit not runningPower issue/full tankCheck plug and outlet; ensure tank is empty and properly seated; reset GFCI if tripped.
Not removing moistureSettings/temperatureCheck humidity setting; ensure room temp is above 41°F; clean air filter; check for blocked airflow.
Water leakingTank/drain hoseEnsure tank is correctly installed; check drain hose connection for leaks; place unit on level surface.
Loud noise/vibrationPlacement/obstructionEnsure unit is level; check for objects touching cabinet; clean filter for proper airflow.
Display not workingPower/control lockCheck power connection; press and hold CONTROL LOCK for 3 seconds to unlock.
Ice on coilsLow temperatureAuto defrost should activate; move to warmer area if below 41°F.

Reset: Unplug for 10 minutes, then restart to reset electronic controls.

Service: 1-800-374-4432; www.frigidaire.com